Xerox Scanner 701P41834 User Manual

Xerox FreeFlow Scanner 665  
Customer Software Release Supplement  
701P41834  
Version 1.0  
May, 2004  
 
TABLE OF CONTENTS  
ii  
 
1. Introduction  
Overview  
This Customer Software Release Supplement (CSRS) is issued  
with the Xerox FreeFlow Scanner 665 to provide customers with  
information specific to the FreeFlow Scanner 665.  
NOTE: This CSRS contains only a Hints and Tips section for the  
FreeFlow Scanner 665.  
Xerox FreeFlow Scanner 665  
The Xerox FreeFlow Scanner 665 is a new Xerox scanner that  
converts documents in digital format and scans 8.5 x 11 inch  
black and white single-sided documents at 65 images per minute  
(ipm) at 600 dpi.  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
1-1  
     
INTRODUCTION  
XEROX FREEFLOW SCANNER 665  
1-2  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
2. Hints and Tips  
Hints and Tips  
The Hints and Tips in this section have been written to support  
the launch of the Xerox FreeFlow Scanner 665.  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
2-1  
   
HINTS AND TIPS  
XEROX FREEFLOW SCANNER 665  
FreeFlow Scanner 665  
Table 2-1 lists Hints and Tips for the FreeFlow Scanner 665.  
Table 2-1. FreeFlow Scanner 665 Hints and Tips  
Feature/Function Hints/Tips  
#
1
Hole Fill  
Regular use of the “Hole Fill” function in the scanner requires daily cleaning  
of the paper guide on the automatic document handler (ADH). The paper  
guide is the long, dark gray, plastic strip on the underside of the ADH, has a  
pattern of very thin images, and two cutouts for the rollers. The following  
steps should be used to clean this part:  
1. Apply “Xerox Lens and Mirror Cleaner (XPN 43P81)” to a clean, lint  
free, non-abrasive cloth.  
2. Lift up the ADH.  
3. Identify the flat, dark gray paper guide on the right-hand, underside of  
the DADH. The paper guide is a long, flat piece of ribbed plastic, 5  
inches from the right-hand side of the DADH. The paper guide is  
approximately 13 inches in length and 1 inch wide and pivots in the  
right/left motion when touched. This part also has two “cutouts” in it with  
two rollers resting in the cutouts.  
4. Rub the cloth in the right-to-left motion across the paper guide, starting  
at the back of the scanner, working your way to the front.  
CAUTION  
Be careful not to dislodge the thin belt near the roller closest to the front  
of the scanner.  
The system may inadvertently white-fill small “blocks” (~3-5 mm in size) of  
a scanned image in areas of the original that are similar to the pattern on  
the document feeder paper guide. To eliminate these white-fill blocks,  
disable the “Hole Fill” option.  
2
“Hole Fill” when  
“Reprocessing”  
The “Reprocess” command does not eliminate holes.  
images in “Preview” If a “Preview” of an image is made with “Hole Fill” turned off, and  
“Reprocess” is selected with “Hole Fill” off or on, the holes will not be  
removed from the previewed image. Holes will be removed from the final  
scan “Accept”.  
3
4
Scanning  
photographs  
Scanning photographs through the document handler is not recommended  
due to the potential for damaging the original, as well as the susceptibility of  
“streaks” in the resultant scanned image.  
Artifacts in  
“Automatic” mode  
Windows < 0.5” x 0.5” are categorized as “background” and subsequently,  
are processed differently from nearby windows (documents with a lot of  
“small sized” content, such as maps with “landmarks” on them, are most  
susceptible to this type of failure). This also occurs when scanning originals  
with light shades of yellow and blue.  
NOTE: If this problem occurs, the document should be scanned in a  
different orientation, or off of the platen glass.  
2-2  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
   
XEROX FREEFLOW SCANNER 665  
HINTS AND TIPS  
Table 2-1. FreeFlow Scanner 665 Hints and Tips  
#
Feature/Function  
Hints/Tips  
5
Fast Preview  
It is recommended that you leave the PC monitor screen resolution at the  
default setting when the system is installed (1024 x 768). If the screen  
resolution is changed from this default, the rulers on the scanner preview  
window may be covered by the preview image, particularly with smaller,  
custom sized originals.  
6
7
More - Pictorial  
Rendering  
The Brightness, Contrast, and Advanced Image Adjustment controls will  
not function if the “Pictorial Rendering” selection (found in the “More” button  
on the “Image Quality” tab) is changed to “Threshold” for any “Original  
Type” other than “Text and Line Art.”  
Background  
Suppression  
Background suppression has improved significantly as compared to the  
“DocuImage 620S Scanner” and the “Production Scanner”. Specifically, the  
“Normal” selection will remove the background on the wider range of  
background darkness levels. Documents with darker backgrounds or  
darker colored stocks that previously required background suppression  
settings of “Strong” or “Very Strong” may no longer require these settings.  
8
9
SCSI scanner  
connection  
It is important to ensure the connectors on the SCSI interface cable that  
connects the scanner to the PC is properly seated and the thumbscrews  
holding the connector are tightened. If the screws on the connector are not  
tightened, the connections, particularly on the scanner, may become loose  
over time, resulting in one of the following fault codes: 62-125, 62-145.  
System calibration  
The scanner image quality may vary slightly for the first 20 - 30 minutes of  
operation if the scanner has been turned off for an extended period of time.  
If the scanner has been turned “off” for longer than 48 hours, it is  
recommended that you calibrate the scanner immediately prior to scanning  
a job for the first 20 - 30 minutes of operation after powering on.  
10 Windows “Found  
New Hardware”  
message  
Upon a reboot of the scanner and the PC, Windows may occasionally  
display a “Found New Hardware” message, despite having completed a full  
installation of the scanner hardware. Assuming the devices were rebooted  
in the proper sequence (scanner first, until the “Ready” light is lit, then the  
PC), this message can be ignored by selecting “Cancel” from the “Found  
New Hardware” dialog.  
11 Pictorial rendering  
warning message  
Changes made to the “Pictorial rendering” selection, followed by a change  
in the “Original Type” selection, may yield a warning, noting that the  
pictorial rendering has been automatically changed (“Warning - setting  
change - the following setting will be reset: Pictorial rendering”).  
NOTE: The “Pictorial rendering” selection is located by selecting the  
“More” button on the “Image Quality” tab of the scanner driver.  
12 Printing Help  
If you attempt to print the full contents of “Help” (Go to Help and choose the  
heading “Solving Problems”, then choose to print “selected heading and all  
subtopics”), the last subtopic entitled “Clearing Jams and Misfeeds” does  
not print and must be printed separately.  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
2-3  
HINTS AND TIPS  
XEROX FREEFLOW SCANNER 665  
Table 2-1. FreeFlow Scanner 665 Hints and Tips  
#
Feature/Function  
Hints/Tips  
13 Low resolution  
scanning of text  
Scanning text printed in 10pt font or less at resolutions of 100 dpi or less  
will result in image content that may be difficult to discern. These low-  
resolution selections are typically used for generating thumbnails. If better  
readability is desired, resolutions of 200 dpi of higher should be used.  
14 Original Types /  
Image File Sizes  
Originals scanned using incorrect “Original Type” selection (scanning a  
halftone in “Photograph” mode, for example) can yield image file sizes that  
are significantly larger than the resultant file size scanned in the correct  
“Original type”.  
15 Second-side show-  
through when  
Originals with a large amount of dark content on the reverse side of a page,  
may exhibit more “show-through” in the resulting scanned image than if  
scanned through the document feeder. If show-through is a problem, place  
a black piece of paper on top of the original being scanned from the platen.  
A stronger “background suppression” setting may also help in removing  
unwanted show-through.  
scanning from the  
platen  
16 Scanner Support  
Unpredictable behavior can result if the scanner diagnostic software  
(“Scanner Support” application) is invoked while the scanner is booting.  
The application should be run with the scanner fully powered off, or fully  
powered on.  
17 Image registration  
18 “Help”  
If scanned images repeatedly contain thin, black lines on the edge of the  
image, run the “Setup Registration” routine in the “Scanner Support”  
application to re-set the scanner’s registration.  
The following information in “Help” about “Scan Tickets” is incorrect:  
1. Within the Twain GUI, go to the Help menu and then the Index —>  
Scan Tickets.  
2. Choose the “Backing up your scan ticket tiles” option.  
3. Part 2 reads: Select [Start: Programs: Windows Explorer] - with  
Windows XP, it should read [Start: Programs: Accessories: Window  
Explorer].  
4. Part 3 reads: “Browse to C:\winnt\Twain_32\Xerox665s\international” -  
with Windows XP, it should read “C:\Program Files\Common  
Files\Xerox\Scanner”.  
The following information in “Help” on “Scanner Specifications” is incorrect:  
1. Within the Twain GUI go to Help --> Index --> Scanner Quick  
Reference --> Document Feeder --> Scanner Specifications.  
2. Note that under the Minimum paper dimensions reads 6.5 x 5.5 inches,  
long edge feed — this should read short edge feed.  
3. Under document Feeder --> Color Spaces & resolutions supported  
Binary B/W reads 76 - 1200 dpi — should read 72, 75, 96, 100, 120,  
150, 200, 240, 300, 400, 600, 1200 dpi.  
19 Electronic Page  
Deskew  
Although the “Electronic Page Deskew” (Options: Preferences) is enabled  
when scanning from the platen or the feeder, it is only functional when  
scanning from the feeder.  
2-4  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
XEROX FREEFLOW SCANNER 665  
HINTS AND TIPS  
Table 2-1. FreeFlow Scanner 665 Hints and Tips  
#
Feature/Function  
Hints/Tips  
20 Scanner driver  
options in 3rd party  
applications  
When using any application other than “DigiPath” to call the scanner driver  
(i.e., PhotoShop), some GUI selections may not be available and/or may be  
set to different default settings. These selection and defaults settings will  
differ from application to application.  
The following sections include more Hints and Tips for the  
FreeFlow Scanner 665.  
“Automatic” mode line screens  
When changing the default resolution in “Automatic” mode, it is  
recommended that you also change the line screen. Line screen  
selections are listed in the “Pictorial Rendering” list box (found in  
the “More” button on the “image Quality” tab). Table 2-2 lists the  
default values for the specific selections and the recommended  
alternative selections:  
Table 2-2. Recommended alternative values  
Default res./default line  
screen  
Alternative res./recommended  
line screen  
“Optimize Image For”  
DocuTech 100/120 Pro  
DocuTech 100/120 C/P  
1200 dpi / 141 lpi  
600 dpi / 125 lpi  
600 dpi /125 lpi  
1200 dpi / 141 lpi  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
2-5  
   
HINTS AND TIPS  
XEROX FREEFLOW SCANNER 665  
DocuTech Original Types  
“DocuTech” Original Type are no longer available with the  
FreeFlow Scanner 665. DocuTech original types are image  
quality selections that would optimize the scanner performance  
such that it produced image quality similar to that which is  
available on the original DocuTech 135. Table 2-3 defines the  
settings on the FreeFlow Scanner 665 that can produce image  
quality similar to what is available on the original DocuTech 135.  
For each desired DocuTech mode be sure to select “Xerox  
DocuTech 6135” as the target printer (“Optimize image for”).  
Table 2-3. FreeFLow 665 Scanner settings  
FreeFlow  
Scanner 665  
Brightness or  
Fine  
Pictorial  
Background Rendering  
DocuTech  
Mode  
“Original Type” Adjustment  
Sharpness Suppression (“More” button)  
Standard  
Paste-Up  
Text and line art  
Test and line art  
Text and line art  
0
1
0
2
5
2
Mild  
Threshold  
Threshold  
Threshold  
Mild  
Colored  
Normal  
Background  
Light Image  
Photograph  
Text and line art  
Photograph  
-10  
2
2
Mild  
Off  
Threshold  
11, 32, 54, 74,  
91  
DocuTech 106 HT  
Halftone  
(30 - 100 lpi)  
Fine Halftone  
18, 36, 50, 64,  
82  
2
4
Mild  
Mild  
DocuTech 106 HT  
Threshold  
Halftone  
(101 - 300  
lpi)  
Coarse Halftone  
0
Photograph  
and text  
Using “IQ  
Windows”:  
Set window 1  
(Entire page) to:  
Text and line  
art  
0
2
2
Mild  
Off  
Threshold  
Set Window 2  
(etc.) to:  
Photograph  
11, 32, 54, 74,  
91  
DocuTech 106 HT  
2-6  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
   
XEROX FREEFLOW SCANNER 665  
HINTS AND TIPS  
Table 2-3. FreeFLow 665 Scanner settings  
FreeFlow  
Scanner 665  
Brightness or  
Fine  
Pictorial  
Background Rendering  
DocuTech  
Mode  
“Original Type” Adjustment  
Sharpness Suppression (“More” button)  
Halftone and  
text  
Using “IQ  
Windows”:  
Set window 1  
(Entire page) to:  
Text and line  
art  
0
2
2
Mild  
Mild  
Threshold  
Set Window 2  
(etc.) to:  
18, 36, 50, 64,  
82  
DocuTech 106 HT  
Fine Halftone  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 
2-7  
HINTS AND TIPS  
XEROX FREEFLOW SCANNER 665  
2-8  
CUSTOMER SOFTWARE RELEASE SUPPLEMENT  
 

Weslo Treadmill cadence 100i User Manual
West Bend Popcorn Poppers 6 quart User Manual
Westcott Camera Accessories 1822 User Manual
Whirlpool Clothes Dryer GCEM2990TQ0 User Manual
Whirlpool Range 9763003 User Manual
Whynter Building Set KS 1100 User Manual
Xerox All in One Printer 4260 XF User Manual
Yale Personal Lift Series Y80 User Manual
Yamaha Home Theater System HTR 6030 User Manual
Zanussi Refrigerator R37F7VFW User Manual